FRONT PANEL LCD DISPLAY
TranScend Chassis – Operation Manual
4-3
Optical
Power (dBm)
Attn (dB)
Prev Menu
Chassis
Temperature(C)
Model
Hardware Version
Software Version
Serial Number
Prev Menu
Prev Menu
Prev Menu
Table 2: TranScend High Sensitivity Quad Return Receiver Front Panel Display Menu Overview
Greeting:
Greeting Message
Press “Select” button to go into the plug-in menu.
Prev Menu:
Press “Select” will bring back to the System menu.
The entries in plug-in menu are described as follows:
Setup Menu:
Attn Setting Menu:
Sel Ch:
Press “Select” to select the channel for attenuation adjustment. Press “Right” or “Left” button to cycle
through available channels.
Attn (dB):
Press “Select” to set the attenuation level. Press “Right” to increase or “Left” button to decrease the
attenuation level.
NOTE: After the attenuation level adjustment, user must press “Select” to commit the attenuation
level in order for the plug-in to operate at such level and for NVRAM storage. Fail to do so, the
attenuation might revert back to previous level.
Save:
Press “Right” or “Left” button to select between “Yes” or “No”. Press “Select” to commit the value into
NVRAM when “Yes” is selected. The value in bracket refl ects the current NVRAM contents. If user presses “Select”
when display is “No”, no NVRAM change takes place.
Test Point Menu:
Select the test point connection to front panel “RF TEST” output.
Sel Ch:
Press “Select” to select the channel to connect to the front panel “RF TEST” output. Press “Right” or “Left”
button to cycle through available channels.
Alarm Enable Menu:
Enable or disable alarms on the selected channel. Note: the alarm’s enable or disable switch
only applies to the analog attributes on per channel basis. These attributes include Optical Power Level, RF and
Laser Temperature.
InnoTrans Communications
HS Quad Return Rcvr
CHAPTER 4: