CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual
5-19
GainControl:
Displays the gain control mode setting.
Example #1: In this example, the module in slot 1 reports its gain control mode.
Transcend [slot-1] >gaincontrol
MGC
FiberLength:
Displays the transmit fiber length setting in kilometer.
Example #1: In this example, the module in slot 1 reports its transmit fiber length.
Transcend [slot-1] >FiberLength
20
km
LaserTempAlarm:
Displays the alarm status of laser temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of laser temperature on channel 1 as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >LaserTempAlarm 1
MajorLoLo
LaserPowerAlarm:
Displays the alarm status of laser power.
Example #1: In this example, the module in slot 1 reports the alarm status of laser power as “MajorLoLo” (e.g.
Major alarm with reading below the low low threshold).
Transcend [slot-1] >LaserPowerAlarm
MajorLoLo
LaserRfAlarm:
Displays the alarm status of laser RF.
Example #1: In this example, the module in slot 1 reports the alarm status of laser RF as “MajorLoLo” (e.g. Major
alarm with reading below the low low threshold).
Transcend [slot-1] >LaserRfAlarm
MajorLoLo
OPinPowerAlarm:
Displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPinPowerAlarm
MajorLoLo
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.