Opera ting Ma nua l a nd Inspection Book
SMART LIFT 2.30 SL, 2.35 SL, 2.40 SL / HYMAX S 3000, 3500, 4000
20110015 OPI
58
Version 1.0
Figure: Selection the Liebig anchor with floor cover (screed, tiles)
Hole diameter 26 mm in the baseplate
Liebig anchor
Anchor type
BM16-25/100/65 BM16-25/100/100
Drill depth (mm)
a
125
125
Min. anchoring depth (mm)
b
100
100
Concrete thickness (mm)
c
Min.200 (*)
Min.200 (*)
Drill diameter (mm)
d
25
25
Component thickness (mm)
e+f
40-65
65-100
Concrete quality
Min.C20/25 normal reinforcement
Number of anchors (pc.)
depending on the lift type
Torque of the anchors
115 Nm
115 Nm
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the
details in the foundation plans.
Similar value anchors and other known brands of anchor manufacturers can be used when
considering the conditions.
(
1
) Description of normal reinforcement:
A normal reinforcement is present if the axis separation in the area of the anchor with a
rod diameter of