![ATT NUSSBAUM HYMAX S 3000 Operating Manual And Inspection Book Download Page 46](http://html1.mh-extra.com/html/att-nussbaum/hymax-s-3000/hymax-s-3000_operating-manual-and-inspection-book_3005316046.webp)
Opera ting Ma nua l a nd Inspection Book
SMART LIFT 2.30 SL, 2.35 SL, 2.40 SL / HYMAX S 3000, 3500, 4000
20110015 OPI
46
Version 1.0
Check electrical components for damage.
-
Plug
-
Reversing switch and LED display
-
During assembly and maintenance always check
the condition of electrical lines. All cables and lines
must be secured so they cannot be crushed, kinked
or contact any rotating components (e.g. V-belt
disc, etc.).
At least 1 x per
year
daily
Optional energy set:
- Electrical socket
- Pneumatic connection
Check for damage.
Check function.
At least 1 x per
year
7.2 Cleaning the lift
A regular and expert clean helps retain the value of the lift.
Additionally, it can also be a pre-requisite for the preservation of guarantee claims for any
eventual corrosion damage.
The best protection for the lift is regular removal of contaminants of any kind.
- This includes above all:
•
De-icing salt
•
Sand, pebbles, earth
•
Industrial dust of all types
•
Water, also in connection with other environmental influences
•
Aggressive deposits of all types
•
Permanent humidity due to insufficient ventilation
The frequency of lift cleaning depends, among other things on the frequency of use, of lift
handling, of workshop cleanliness, and the location of the lift. Furthermore, the degree of
contamination depends on the time of year, the weather conditions and workshop ventilation.
Under adverse circumstances, weekly lift cleaning might be required, however a monthly cleaning
may be sufficient.
Do not use and aggressive and abrasive materials for cleaning, rather use mild cleaners, e.g. a
commercially available detergent and lukewarm water.
-
For cleaning, do not use high pressure washers (e.g. steam cleaners)
-
Carefully remove all contamination with a sponge, or if required with a brush.
-
Make sure that there is no residue of the cleaner on the lift.
-
Dry the lift with a cloth and spray it with a spray wax or oil.
-
Moving parts (bolts, bearing zones) are to be lubricated or oiled according to instructions.
-
When cleaning the workshop floor ensure that no aggressive cleaning materials come into
contact with lift surfaces. Permanent contact with any kind of liquid is prohibited.