Figure 16:
Measurement
instrument
•
The measurement device, as can be seen in Figures 16 and 17 on the polyflex belt.
•
The dial gauge may only be turned a minimum of 1 rotation (1 mm) to a maximum of
1.5 rotations (1.5 mm) anti-clockwise.
Figure 17: Place the dial gauge on the belt
•
The fastening screws are to be placed into the starting position again.
7.4 Check / exchange the lift nut system
•
Optical wear measurement:
Catch bar fixation "Safety kit" must be integrated, see Section 9.1.
To check the carrier nut, the cover of the lift spindle must be removed. A carrier nut wear gauge
pin is integrated into the carrier plate. This must be flush with the upper edge of the carrier plate
(in the lifting rail, top) - see Figure below. If the pin peaks out 2 mm from the top, the carrier nut
and the follower nut must be exchanged.
Figure 18: The
lift nut pin is
provided with
a sealing wax