![Atop SW5501C User Manual Download Page 20](http://html1.mh-extra.com/html/atop/sw5501c/sw5501c_user-manual_3004805020.webp)
SW5502C
Wireless Serial Server
User Manual
Getting Started
3.7
Factory Default Settings
Upon arrival, the device is set with factory default settings
.
The SW550XC Series comes with two different IP
addresses for LAN and WLAN as shown below
.
Table 3
.
4
Factory Default Network Settings
Interface
Device IP
Subnet mask
Gateway IP
DNS1
LAN
10
.
0
.
50
.
100
255
.
255
.
0
.
0
10
.
0
.
0
.
254
168
.
95
.
1
.
1
WLAN
192
.
168
.
1
.
1
255
.
255
.
255
.
0
192
.
168
.
1
.
254
Other relevant factory
default settings are summarized as shown below
.
Table 3
.
5
SW550XC Series Factory Default Settings
Parameter
Default Values
Security
User Name
Admin
Password
default
Serial
COM1
RS
-
232, 9600 bps, 8 data bits, No Parity bit, 1 stop bit, No Flow Control
Packet Delimiter timer
:
Auto
COM2
SNMP
SysName of SNMP
0060E9XXXXXX
SysLocation of SNMP
Location
SysContact of SNMP
Contact
SNMP
Disabled
Read Community
public
Write Community
private
SNMP Trap Server
0
.
0
.
0
.
0
Note
:
you can press the
“
Reset
”
button on the front panel for 5 seconds to restore the SW550XC Series to the
factory default settings
.