Control panel appearance
Description:
1.
Thermometer
– monitors the temperature of water exiting the boiler
2.
Main switch
– allows for completely shutting down boiler if necessary (restart the pellet burner)
3.
Control thermostat
– regulates the operation of the pellet burner and also (with the D20P, D30P,
D40P, D50P models) regulates the extraction ventilator. The regulation is based on the temperature of
water exiting the boiler.
4.
Pump thermostat
– serves for switching the pump placed in the boiler circuit (set it to temperature be-
tween 70 – 80 °C).
5.
Safety irreversible thermostat
– serves as boiler protection against overheating in case of control ther-
mostat failure or as an indication of exceeding the emergency temperature. If such exceeding occurs, it
is then necessary to depress the thermostat.
7.
Fuse (6.3 A)
- T6,3A/1500 - type H pellet burner electronics protection.
8.
Area for electronic regulation
of the heating system can be used to house any type of regulation that
fits into an aperture of 92x138 mm. The electric harness is prefabricated and ready to be used for the
regulation’s power supply.
9.
Automatic ash removal switch -
it serves to switch on or off the ash removal when needed eg. in case
of cleaning the ash-pan. By switching off and then on you activate the ash removing module so that it
stops its sound signal and starts the automatic function of the ash removal.
10.
Burner switch
– it serves to switch on or off the burner
1. Thermometer
2. Main switch
3. Control thermostat (for boiler)
4. Pump thermostat
5. Safety thermostat
7. Fuse - T6,3A/1500 - type H
8. Area for electronic regulation of
the heating system (92x138 mm)
9. Automatic ash removal switch
10. Burner switch