of potential burns from hot boiler parts and systems. You must never leave unattended children near
boiler that is in operation. During the operation of solid fuel boilers it is prohibited to use any flam
-
mable liquids for lighting the fire and it is also prohibited to increase the nominal output of the boiler
during operation (overheating).
You must not put flammable objects on the boiler and near the
fuel feeding and ash pan openings and ash must be stored in non-flammable containers with a
lid.
When handling fuel and ash, wear protective equipment (gloves, dust mask). Boilers in operation
must be under occasional supervision of the operator. The user may only carry out repair consisting
in simple replacement of a spare part (e.g. a sealing cord, etc.). During the operation check the doors
and cleaning openings for tightness and always tighten them properly. The user must not alter the
structure and electric installation of boilers. The boiler must always be cleaned properly and in time
so that free passage of all the ways can be guaranteed. Cleaning doors must always be properly closed.
CAUTION
- Follow valid fire regulations and have in reach portable fire extinguisher. If
any non-standard behavior of the boiler shut down the boiler from operation and call the
service.
34. Possible failures and troubleshooting
Failure
Cause
Solution
The “mains” indicator
does not light up
- no mains voltage
- incorrectly plug connector of
power cord in the boiler side
hood
- faulty main switch
- defective cord
- check
- check
- replace
- replace
Boilers do not reach their
required outputs and the
pre-set water tempera-
tures
- little water in the heating
system
- high output of the pump
- the output of the boiler is not
sufficiently sized for the par
-
ticular hot-water system
- poor quality fuel (high mois-
ture content, large pieces)
- poor-quality fuel - pellets
- low chimney draft
- high chimney draft
- bent vanes of the extraction
fan
- insufficiently cleaned boiler
- clogged inlet of combustion
air to the burning chamber
- replenish
- adjust the flow and pump control
- design issue
- burn dry wood and split logs in
halves
- burn high-quality pellets
- new chimney, unsuitable connec-
tion
- install a throttling flap in the flueor
a pressure reducer
- straighten the vanes (to the angle
of 90°)
- replace
- clean
- clean burning little chamber and
burning chamber
Leaky doors
- faulty glass cord
- low chimney draft
- replace
- adjust the door hinges
- fault in the chimney