- 25 -
Operating instructions SunCool
TM
10.2 SunCool
TM
units for SUNTEST XLS / XLS+ weathering units
10
Specifications
Electrical system:
SunCool
TM
version 115V/60Hz:
• Mains voltage:
115 V ± 10%, 60 Hz
• Mains connection:
NEMA 5-15
• Starting current:
34 A (temporary)
• Current consumption:
11.5 A
• Protection:
15 A
• Power consumption:
1.26 kW (max.)
SunCool
TM
version 230V/50Hz:
• Mains supply:
230 V ± 10%, 50 Hz
• Mains connection:
(1, N, PE) AC or
(2, PE) AC
• Starting current:
34 A (temporary)
• Current consumption:
6.3 A
• Protection:
16 A
• Power consumption:
1.26 kW (max.)
Refrigerant:
SunCool
TM
version 115V/60Hz:
Refrigerant:
R 22
Capacity:
480 g
SunCool
TM
version 230V/50Hz:
Refrigerant:
R 407 C
Capacity:
780 g
Dimensions and weight:
SunCool
TM
version 115V/60Hz:
• Dimensions in mm:
600 x 555 x 375
(Width x depth x height)
SunCool
TM
version 230V/50Hz:
• Dimensions in mm:
630 x 620 x 375
(Width x depth x height)
• Weight:
44 kg w/o connections
Noise emission:
• Noise level:
51 dB (A)
Performance:
SunCool
TM
version 115V/60Hz:
• Volume flow (room):
620 m
3
/h
• Cooling performance:
3.5 kW
SunCool
TM
version 230V/50Hz:
• Volume flow (room):
620 m
3
/h
• Cooling performance:
3.5 kW
Ambient conditions:
• Room temperature:
22 °C to 40 °C.
• Relative humidity:
30% - 80%
• Air pressure:
700 - 1060 hPa