MINOR FAULTS
Single long beep. Will reset once the fault is cleared.
Seat swiveled out of position
Edge safety detected
Footrest
Current overload condition
A low battery voltage condition
PULSING BEEP
An intermittent beep for 30-seconds indicates that the
lift has been stopped off the charge station. This repeats
every 5 minutes until the lift is returned to the charge
station. It is recommended that the lift be immediately
moved to a charge strip station located at either end of
the rail.
MANUAL OVERRIDE OPERATION
If your lift fails to operate and the operator is unable to
exit the lift on the stairway, another person may use the
optional manual override tool to lower or raise the lift to
a landing. However, please follow the instructions on the
bottom safety flap of the lift and turn the on/off switch to
“Off”. Insert the manual override tool into the hole in the
lower safety flap until it engages the motor shaft, then turn
in the direction desired.
Do not operate the lift with the manual
lowering tool engaged.
NOTE: Depending on your model, a 6mm or 7mm nut driver or socket
can be used to manually lower the lift.