2920 1257 04
46
Instruction book
7.6.2 60 Hz
Compressor type
LT15
LT22
LT40
LT55
LT75
LT110
LT150
Maximum working pressure . . . . . . . . . . bar(e)
20
20
20
20
20
20
20
Temperature at outlet valve, approx.
- Unsilenced compressor . . . . . . . . . . . . Celsius
40
53
65
50
43
49
68
- Silenced compressor . . . . . . . . . . . . . . Celsius
48
61
73
58
51
57
76
Power input at max. working pressure . . kW
2.48
3.11
5.14
6.66
9.86
12.86
15.57
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min
1800
1800
1800
1800
1800
1800
1800
Free air delivery 2) . . . . . . . . . . . . . . . . . l/s
2.7
3.6
6.3
8.4
13.6
17.0
19.9
Oil capacity . . . . . . . . . . . . . . . . . . . . . . . l
0.8
0.8
0.8
1.4
1.7
1.7
1.7
Opening pressure of relief valve . . . . . . bar(e)
6.5
6.5
6.5
6.5
6.5
6.5
6.5
Maximum sound pressure level 1)
- Standard version . . . . . . . . . . . . . . . . . . dB(A)
80
81
81
82
83
84
85
- Silenced receiver-mounted version . . . dB(A)
67
68
68
72
72
75
75
- Silenced pack version . . . . . . . . . . . . . dB(A)
65
66
66
70
70
72
72
7.7 Compressor data for LT 30 bar
7.7.1 50 Hz
Compressor type
LT22
LT40
LT55
LT75
Maximum working pressure . . . . . . . . . . . . . . . . . . . . . . bar(e)
30
30
30
30
Temperature at outlet valve, approx.
- Unsilenced compressor . . . . . . . . . . . . . . . . . . . . . . . . Celsius
49
60
42
58
- Silenced compressor . . . . . . . . . . . . . . . . . . . . . . . . . . Celsius
57
68
50
66
Power input at max. working pressure . . . . . . . . . . . . . . kW
2.83
4.73
6.11
7.89
Motor shaft speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . r/min
1500
1500
1500
1500
Free air delivery 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l/s
2.5
4.4
6.4
8.5
Oil capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l
0.8
0.8
1.4
1.4
Opening pressure of relief valve . . . . . . . . . . . . . . . . . . bar(e)
6.5
6.5
6.5
6.5
Maximum sound pressure level 1)
- Standard version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dB(A)
79
79
80
81
- Silenced pack version . . . . . . . . . . . . . . . . . . . . . . . . . dB(A)
64
64
68
68
Summary of Contents for LE110
Page 11: ...2920 1257 04 11 Instruction book Fig 2 2 Dimension drawing LE LT55 75 and LF40 55 Power Pack ...
Page 19: ...2920 1257 04 19 Instruction book Fig 2 10 Dimension drawing LE LT15 up to 40 Unsilenced Pack ...
Page 21: ...2920 1257 04 21 Instruction book Fig 2 12 Dimension drawing LE LT15 up to 150 with CD dryer ...