6 Problem solving
1
Insufficient air pressure
a
Air leak
a
Check and correct as necessary
b
Air filter choked
b
Replace filter
c
Air pressure switch incorrectly set
c
Adjust switch
d
Air consumption exceeds maximum output of compressor
d
Check equipment connected
e
Damaged valve
e
Inspect valves and replace parts where necessary
f
Unloader 1) malfunctioning
f
Inspect and replace parts where necessary
g
Solenoid valve 1) out of order
g
Remove and check. Replace if necessary
2
Unit does not speed up
a
Voltage drop at motor terminals
a
Consult power supplier. Use correct size of cable
b
Unloader malfunctioning
b
See 1f
c
Solenoid valve out of order
c
See 1g
d
Blow-off silencer 1) choked
d
Replace
3
Air receiver pressure rises above maximum and causes
safety valve to blow
a
Air pressure switch or pilot valve 1) incorrectly set or out
of order
a
Check. Replace switch or valve, if necessary
b
Solenoid valve defective
b
See 1g
c
Unloader malfunctioning
c
See 1f
d
Blow-off silencer choked
d
See 2d
4
Relief valve blows 1)
a
Defective inlet valve in HP cylinder head
a
Inspect and replace part(s) as necessary
b
Relief valve not airtight
b
Replace valve
5
Receiver does not hold pressure
a
Check valve leaks
a
Check for broken valve and springs
b
Air leaks
b
Check and correct as necessary
6
Too frequent starting/too short operating periods
a
Air pressure switch or pilot valve 1) incorrectly set
a
Increase pressure difference
b
Check valve leaks
b
See 5a
7
High oil consumption on LE/LT compressors
a
Oil level too high
a
Do not overfill crankcase. Keep level in red circle of sight-
glass
b
Piston ring(s) worn or broken
b
Have condition of piston rings checked
8
Unit does not start
a
Electrical failure
a
Have electrical system checked. Check fuses and line
terminals for tightness
b
Overload relay cut out
b
Reset overload relay. If the relay cuts out again after
starting, see point 9
c
Air pressure above pre-set starting pressure
c
Compressor will start when air pressure is lower than pre-
set starting pressure of air pressure switch
9
Overload relay cuts out
a
Overload relay incorrectly set
a
Check and adjust. Reset relay
b
Solenoid valve out of order
b
See 1g
c
Unloader plunger jammed
c
See 1f
d
Blow-off silencer choked
d
See 2d
e
Ambient temperature too high
e
Improve ventilation of room
f
Motor stops and starts too frequently
f
See 6
g
Overcurrent due to motor or compressor failure
g
Have motor line current measured. If currents exceed rated
motor current, have compressor inspected; if currents are
not equal, have motor inspected
Footnote chapter 6
1) If provided.