2920 1257 04
42
Instruction book
7 Principal data
7.1 Reference conditions
Inlet pressure (absolute) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar
1
Relative air humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . %
0
Air inlet temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . celsius
20
Working pressure:
- for LE 10 bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
7
- for LF 10 bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
7
- for LT 15 bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
12
- for LT 20 bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
20
- for LT 30 bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
30
7.2 Limitations
Minimum inlet temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . celsius
0
Maximum inlet temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . celsius
40
Maximum working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . bar(e)
See below
7.3 Compressor data for LE 10 bar
7.3.1 50 Hz
Compressor type
LE15
LE22
LE40
LE55
LE75
LE110
LE150
Maximum working pressure for LE . . . . bar(e)
10
10
10
10
10
10
10
Maximum working pressure for
LE Trolley . . . . . . . . . . . . . . . . . . . . . . . bar(e)
9.5
9.5
9.5
9.5
9.5
9.5
9.5
Pre-set pressure difference for
LE Trolley . . . . . . . . . . . . . . . . . . . . . . . bar
1
1
1
1
1
1
1
Temperature at outlet valve, approx.
- Unsilenced compressor . . . . . . . . . . . . Celsius
40
44
66
59
80
65
91
- Silenced compressor . . . . . . . . . . . . . . Celsius
48
52
74
67
88
73
99
Power input at max. working pressure . . kW
1.82
2.54
4.57
6.11
8.28
10.69
14.92
Motor shaft speed . . . . . . . . . . . . . . . . . . r/min
1500
1500
1500
1500
1500
1500
1500
Free air delivery 2) . . . . . . . . . . . . . . . . . l/s
3.4
4.4
8.4
11.7
15.7
18.6
23.9
Oil capacity . . . . . . . . . . . . . . . . . . . . . . . l
0.8
0.8
0.8
1.4
1.4
1.7
1.7
Opening pressure of safety valve (not
for Block/Power Pack) . . . . . . . . . . . . . . bar(e)
11
11
11
11
11
11
11
Maximum sound pressure level 1):
- Standard version . . . . . . . . . . . . . . . . . . dB(A)
78
79
79
80
81
84
85
- Silenced receiver-mounted version . . . dB(A)
65
66
66
70
70
73
73
- Silenced pack version . . . . . . . . . . . . . dB(A)
63
64
64
68
68
70
70