Description
Phase
Description
1
Install the compressor on a level floor suitable for taking its weight. For ventilation
alternative 1 (indicated as Alt. 1), the minimum distance between the top of the bodywork
and the ceiling is 1200 mm (47 in).
2
Remove the plastic plug (if provided) from the compressor air outlet pipe and fit the air
outlet valve (to be provided by the customer) to the pipe. Close the valve and connect it
to the net.
3
The pressure drop over the air outlet pipe can be calculated as follows:
dp = (L x 450 x Qc
1.85
) / (d
5
x p)
d = Inner diameter of the outlet pipe in mm
dp = Pressure drop (recommended maximum = 0.1 bar)
L = Length of outlet pipe in m
p = Absolute pressure at the compressor outlet in bar(a)
Qc = Free air delivery of the compressor in l/s
It is recommended that the connection of the compressor air outlet pipe is made on top of
the main air net pipe in order to minimise carry-over of possible condensate residue.
As a rule of thumb, the following formula can be used to calculate the recommended
volume of the air net:
V = (30 x C x p x Q) / Dp
C = Correction factor
Dp = Pressure difference between unloading and loading pressures in bar (recommended
minimum = 0.6)
p = Compressor inlet pressure in bar absolute
Q = Free air delivery of compressor in l/s
V = Recommended air net volume in l
Correction factors
Air consumption divided by compressor free air delivery
Correction factor C
0.9
0.10
0.8
0.15
0.7
0.20
0.5
0.25
0.3
0.20
0.2
0.15
0.1
0.10
Instruction book
2920 1475 06
65
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......