Compressor
type
Supply
voltage (V)
Overload relay
(A)
Fuses Class gL/
gG (Type 2) (A)
2X3 fuses
2X3 cables to
contactor
Fuses Class gL/
gG (Type 2) (A)
3 fuses
2X3 cables to
contactor
Fuses Class gL/
gG (Type 2) (A)
3 fuses
3 cables to
contactor
(bridges to be
installed by
customer)
GA 250
400
289
2x (3x355)
--
--
GA 250
500
234
2x (3x300)
--
--
60Hz IEC compressors with ABB motors
GA 90 up to GA 315 and GR 110 up to GR 200
Compressor
type
Supply
voltage (V)
Overload relay
(A)
Fuses Class gL/
gG (Type 2) (A)
2X3 fuses
2X3 cables to
contactor
Fuses Class gL/
gG (Type 1) (A)
3 fuses
2X3 cables to
contactor
Fuses Class gL/
gG (Type 1) (A)
3 fuses
3 cables to
contactor
(bridges to be
installed by
customer)
GA 90
220-230
208
2x (3x300)
--
--
GA 90
380
122
2x (3x160)
3x250
--
GA 90
440-460
104
2x (3x160)
--
3x224
GA/GR 110
220-230
257
2x (3x355)
--
--
GA/GR 110
380
149
2x (3x200)
3x300
--
GA/GR 110
440-460
129
2x (3x160)
3x300
--
GA/GR 160
380
195
2x (3x250)
3x400
--
GA/GR 160
440-460
169
2x (3x224)
--
--
GA/GR 200
380
242
2x (3x355)
--
--
GA/GR 200
440-460
204
2x (3x300)
--
--
GA 250
380
284
2x (3x400)
--
--
GA 250
440-460
246
2x (3x315)
--
--
GA 315
380
319
2x (3x400)
--
--
GA 315
440-460
278
2x (3x355)
--
--
60 Hz CSA/UL compressors with Siemens or Weg motor
GA 90 up to GA 315 and GR 110 up to GR 200
Instruction book
114
2920 1475 06
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......