Compressor type
Supply
voltage (V)
Circuit
breakers
Transforme
r T1
250 VA
Transforme
r T1
400 VA
Transforme
r T1
630 VA
Transforme
r T1
800 VA
GA/GR 160
220-230
Q1
1.6
2.4
3.7
4.7
GA/GR 160
380
Q1
0.9
1.4
2.2
2.8
GA/GR 160
440-460
Q1
0.8
1.2
1.9
2.4
GA/GR 160
575
Q1
0.6
0.9
1.4
1.8
GA/GR 200
380
Q1
0.9
1.4
2.2
2.8
GA/GR 200
440-460
Q1
0.8
1.2
1.9
2.4
GA/GR 200
575
Q1
0.6
0.9
1.4
1.8
GA 250
380
Q1
0.9
1.4
2.2
2.8
GA 250
440-460
Q1
0.8
1.2
1.9
2.4
GA 250
575
Q1
0.6
0.9
1.4
1.8
GA 315
380
Q1
0.9
1.4
2.2
2.8
GA 315
440-460
Q1
0.8
1.2
1.9
2.4
GA 315
575
Q1
0.6
0.9
1.4
1.8
9.7
Compressor data
Attention
On compressors with a DD filter installed, the maximum working pressure is 0.35 bar (5.07
psi) lower than the maximum working pressure stated below. The nominal working pressure
is 0.1 bar (1.45 psi) lower than the nominal pressure stated below.
Data for GA 7.5 bar (109 psi) 50 Hz compressors
Units
GA90
GA110 GA132 GA160 GA200 GA250
Maximum working pressure, GA Pack
bar(e)
7.5
7.5
7.5
7.5
7.5
7.5
Maximum working pressure, GA Pack
psig
109
109
109
109
109
109
Maximum working pressure, GA Full-
feature
bar(e)
7.25
7.25
7.25
7.25
7.25
7.25
Maximum working pressure, GA Full-
feature
psig
105
105
105
105
105
105
Nominal working pressure
bar(e)
7.0
7.0
7.0
7.0
7.0
7.0
Nominal working pressure
psig
102
102
102
102
102
102
Motor shaft speed
r/min
1490
1490
1490
1490
1490
1490
Power input, GA Pack
kW
103
124
147
178
224
272
Power input, GA Pack
hp
138
166
197
239
300
365
Power input, GA Full-feature
kW
110
131
156
188
241
289
Power input, GA Full-feature
hp
148
176
209
252
323
388
Power input, GA W Pack
kW
100
121
142
173
216
264
Power input, GA W Pack
hp
134
162
190
232
290
354
Instruction book
2920 1475 06
121
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...