Protection from rain
The rain protection prevents rain from entering the machine. At the same time it protects the display of the
Elektronikon regulator against sun and rain.
High ambient temperature (HAT)
The compressor is specially designed for continuous operation under humid and high ambient temperature
conditions. The maximum ambient temperature is 50˚C (122˚F).
Phase Sequence Relay
The phase sequence relay prevents the drive motor from rotating in the wrong direction.
PT 1000/100 Thermal motor protection
Not available for GA 110, GA 250, GA315 , GA 355, GA 500, GR 160 and GR 200.
The PT1000/100 thermal protection provides protection for the drive motor. Five sensors are installed in the
motor, two to measure the temperature of the bearings and three to measure the temperature of the windings.
The readings can be called up on the display of the Elektronikon regulator. A message will appear on the
display and the general alarm LED will light up if one of the temperatures exceeds the shut-down warning
setting.
Pipe connections
This compressor can be equipped with:
ISO connections for GA 90 up to GA 160, GA 315 50 Hz, GA 355 up to GA 500 and GR 110 up to GR200.
NPT connections for GA 90 up to GA 160 and GR 110 up to GR200.
Tube coolers
Not available for GA 110 and GR 110 up to GR 200.
The compressor is equipped with tube and shell coolers.
SPM monitoring
A number of vibration sensors are provided on the drive motor and compressor elements. The readings can
be called up on the display of the Elektronikon regulator.
Instruction book
2920 1475 06
13
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......