Procedure
Starting from the Main screen (see
):
• Press the key “Menu” (F1).
• Press the arrow down key (1) until “Service” is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2).
• A screen similar to the one below appears:
“Service Timer”
“Running Hours”
7971 “hrs”
“Menu”
“Reset”
F1
F2
F3
• The screen shows that the total compressor running time is 7971 hours.
• Press the tabulator key (2), following screen appears:
“Next Timer”
“Level”
A B
8000 “hrs”
“Back”
“Reset”
F1
F2
F3
• The screen shows that the next service plans to be carried out are plans A and B and that these plans are
to be carried out every 8000 running hours.
• Press the arrow down key (1) to find out which service plans were carried out previously, following screen
appears:
“Previous Timer”
“Level”
A
4008 “hrs”
“Back”
F1
F2
F3
• The screen shows that plan A was carried out at 4008 running hours.
• Stop the compressor, switch off the voltage and carry out the service operations related to the indicated
service plans, see section
Preventive maintenance schedule.
• Switch on the voltage and scroll to the “Next Timer” service screen.
• Press the “Reset” button (F3). Confirm the question for resetting.
The “Reset” button only appears when the “Next Timer” level is almost reached.
After pressing the arrow down key in the “Service Timer” screen, the “Life Time” hours are
shown, i.e. the number of hours elapsed since initial programming ex-factory. This timer is
not taken into account.
Instruction book
48
2920 1475 06
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......