The product you have just purchased has undergone numerous tests and inspections to guarantee the highest quality. We hope it will give you entire
satisfaction.
INSTALLATION OF THE PANEL HEATER
Please read the instructions before starting to install the heater. Disconnect
the power before carrying out any work on the heater. Keep these
instructions even once you have installed your heater.
1) Where to install your heater ?
- This equipment was designed to be installed in a residence. Please ask your
distributor before using it for any other purpose.
- The panel heater should be installed according to normal trade practice and in
compliance with legislation in the relevant country (the IEE Wiring Regulations).
- The equipment is class 2
and is protected against splashed water IP
24. The device is to be installed so that switches and other controls cannot
be touched by a person in the bath or shower, except in the UK where IEE
Regulations 701.512.2 and 701.512.3 apply. These allow the use of IP24
rated products and their integral controls in Zone 2 and outside zones.
a
- Comply with the minimum clearance distances for positioning of the panel
heater.
b
- If your wall covering is laid on foam, a spacer the same thickness as the
foam must be placed under the panel heater’s support. This ensures there is
free space behind the panel heater to make sure its control settings are not
adversely affected.
- Do not install the panel heater:
c
In a draught that might affect adjustment (for example, under a
central mechanical ventilation unit etc...).
c
Under a fixed mains power socket.
c
In zone 1 of bathrooms
a
.
It is forbiden to install vertical product in horizontal position.
2) How to install the panel heater ?
2-1) Release the appliance’s hook-on bracket
We recommend that you place the radiant panel flat, face down.
Have a straight head screwdriver to hand.
2-2) Fix the hook-on bracket
Use the wall-mounting bracket as a template for positioning the heater.
Drilling points A
Drilling points B
2-3) Connecting the panel heater
- The appliance should have a 230-240V 50Hz power supply.
- The panel heater must be connected to the mains, either by a 3-wire cable
(Brown= Phase, Blue = Neutral, Black = Pilot wire) by means of a connexion
box.
In humid areas such as bathrooms and kitchens the power socket must be
installed at least 25 cm above the floor.
- The installation should be fitted with a double pole break device with a break
of at least 3 mm.
- Connection to earth is prohibited. Do not connect the pilot wire
(black) to earth.
- The heater must be installed by a qualified electrician in accordance with
the local regulations. The heater and the pilot wire (black) must
NOT be
connected to earth. If the power cable is damaged, it must be replaced by
the manufacturer or its after-sales service Department or a similary qualified
person to avoid any risk.
If a pilot or piloted panel heater is protected by 30mA differential (e.g.
bathroom) the pilot wire’s power must be protected on this differential
!
CONDITIONS DE GARANTIE :
DOCUMENT À CONSERVER PAR L’UTILISATEUR
(présenter le certificat uniquement en cas de réclamation)
- La durée de garantie est de 2 ans à compter de la date d’installation ou d’achat et ne saurait excéder 30 mois à partir de la date de fabrication en l’absence de
justificatif.
- La garantie couvre l’échange ou la fourniture des pièces reconnues défectueuses à l’exclusion de tout dommage et intérêts.
- Les frais de main d’œuvre, de déplacement et de transport sont à la charge de l’usager.
- Les détériorations provenant d’une installation non conforme, d’un réseau d’alimentation ne respectant pas la norme NF EN 50160, d’un usage anormal ou du non
respect des prescriptions de la dite notice ne sont pas couvertes par la garantie.
- Présenter le présent certificat uniquement en cas de réclamation auprès du distributeur ou de votre installateur, en y joignant votre facture d’achat.
- Les dispositions des présentes conditions de garantie ne sont pas exclusives du bénéfice au profit de l’acheteur, de la garantie légale pour défauts et vices cachés qui
s’appliquent en tout état de cause dans les conditions des articles 1641 et suivants du code civil.
TYPE DE L’APPAREIL *
: _____________________________________________________________________________________________
N° DE SÉRIE *
: _____________________________________________________________________________________________
NOM ET ADRESSE DU CLIENT
: _____________________________________________________________________________________________
*Ces renseignements se trouvent sur la plaque signalétique située sur le côté droit de l’appareil
SATC
Service Assistance Technique Client
ZI Nord - Rue Monge
85002 LA ROCHE SUR YON
Tél. : 02 51 44 34 67
02 51 44 34 26
Fax : 02 51 37 98 27
CACHET DE L’INSTALLATEUR
Les appareils munis de ce symbole ne doivent pas être mis avec les ordures ménagères,
mais doivent être collectés séparément et recyclés.
La collecte et le recyclage des produits en fin de vie doivent être effectués selon les
dispositions et les décrets locaux (DEEE 2002/96/CE).
F117_electro_1280-1432.indd 6
01/04/11 11:57