Appendix
193
Restoring Factory Default Settings
You can restore the factory default settings (listed on the next page) for the
CS1708i / CS1716i. With this procedure, the administrator and all user
accounts are removed from the system. All port names and setting are also
removed.
Note:
1. A jumper cap is required when performing this procedure.
2. If your Administrator login information has become corrupted, or you
have forgotten it), this procedure to reset the original defaults (see
page 27).
1. Unplug the CS1708i / CS1716i’s power adapter.
2. Place a jumper cap over pins 1-2 of the mainboard jumper labeled J17.
3. Plug in the power adapter. The following directions appear on the KVM
console screen:
USERNAME AND PASSWORD INFORMATION AND PORT/USER
INFORMATION HAS BEEN CLEARED. PLEASE POWER OFF THE
SWITCH, REMOVE THE JUMPER, CLOSE THE CASE, THEN
RESTART.
4. Unplug the power adapter again.
5. Remove the jumper cap from the jumper.
6. Close the housing and plug the power adapter in again.
After powering on the unit, you can use the default username and
password to log in.
Summary of Contents for CS1708i
Page 1: ...KVM over IP CS1708i CS1716i Full HD Version User Manual www aten com ...
Page 16: ...CS1708i CS1716i User Manual xvi This Page Intentionally Left Blank ...
Page 26: ...CS1708i CS1716i User Manual 10 Rear Panel CS1708i CS1716i 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ...
Page 28: ...CS1708i CS1716i User Manual 12 This Page Intentionally Left Blank ...
Page 38: ...CS1708i CS1716i User Manual 22 Daisy Chain Installation Diagram ...
Page 64: ...CS1708i CS1716i User Manual 48 This Page Intentionally Left Blank ...
Page 122: ...CS1708i CS1716i User Manual 106 This Page Intentionally Left Blank ...
Page 164: ...CS1708i CS1716i User Manual 148 This Page Intentionally Left Blank ...
Page 166: ...CS1708i CS1716i User Manual 150 This Page Intentionally Left Blank ...
Page 216: ...CS1708i CS1716i User Manual 200 ...