Type:
display the type of event you are creating or modifying
•
Name:
here you can specify a name for the event created. Default is Event X
•
Priority:
here you can adjust the priority of the event. 20 is the lowest, 0 is the highest
•
Attrib:
here you can specify if this event is a security one or not. See
to learn
more about the security option
______________________________________
•
Next Event:
here you can select the event to start after the current on is finished
______________________________________
•
Active at Start:
Ticking this option allows user to close an output contact (Logic Output channel)
in two different manner. Static will close it until the event stop and Pulse will generate a closing
pulse whose length can be defined from 50 to 60000 ms.
•
Active at Stop:
This option is used to create a closing contact pulse when the event is finished.
The length of the pulse can be defined from 50 to 60000 ms.