Reference
GB1400 User Manual
3-67
Test Squelch (SQUEL)
Format:
F1:ESC F4:SET
ON ERROR SQUELCH = ccc
Menu:
TEST
Function Name:
SQUEL
Instruments:
Analyzer only
Options:
None required. This is a standard feature.
Application:
Use this function to enable or disable squelching of On-Error
reports.
Parameters:
On Error Squelch (ccc): Set to ON or OFF
Notes:
When On Error Squelch is ON, the analyzer will squelch
(temporarily stop printing) On Error reports after ten
consecutive reports, that is ten consecutive seconds in which
BER exceeds the current test threshold. On Error reports will
resume after 10 consecutive seconds in which the BER does
not exceed the test threshold.