![ATA 907500 Technical Data Manual Download Page 30](http://html1.mh-extra.com/html/ata/907500/907500_technical-data-manual_2995158030.webp)
30
WARNING
The appliance is to be used for washing dishes, glasses, cutlery and trays.
1)
Read the instructions carefully before installation, use and maintenance of the appliance.
2)
The installation has to be performed by qualified personnel following the manufacturer's
instructions given in the provided manual.
3)
The appliance should only be used by trained personnel.
4)
In the event of breakdown or malfunction, switch off the appliance and seek help exclusively from
an authorized technical assistance center.
5)
Only use genuine spare parts; otherwise no liability is assumed by the manufacturer.
INSTALLATION
JOINING UNITS
If the appliance is delivered as divided into different units, connect the units mechanically, electrically
and hydraulically as follows.
Remove the frontal panels of the units to be connected together.
Stick the provided seal on the tank profile of the racks way on the additional unit.
Place the units together according to the appliance (see the
OVERALL DIMENSIONS
section).
ATTENTION!
Level the units by lowering or raising the adjustable feet; then check
their level against the floor and their alignment side by side. Only if these requirements have
been met, the following point 4. will be carried out easily: the inspection doors will close
perfectly; their micro switches will work well; the conveyor will be straight aligned.
Insert the provided steel edge covers into the sides of the profile of the racks way and fix them
with some screws, so to join the units together.
Fix the lower part of the units together with the provided screws.
Connect electrically the cables of the additional units to the connectors on their appropriate
bracket; follow the numbers on the connectors themselves (see also the provided wiring
diagram).
Connect the appliance to the equipotential system by fixing the yellow/green cable on the lower
part of the appliance where marked as
.
Connect the drain hose of the additional units to the main drain hose of the appliance.
Connect the internal conveyor by using the appropriate joints placed on the conveyor.
Put the frontal panels back into their place.