42
Software
2. The Force Conveyor Measurement screen appears (Figure 6-29). To start the speed
measurement, click on the
Force Conveyor Running
button. A message will display
prompting you to wait until conveyor speed measurement is finished. Check that the
conveyor moves and wait for the measurement to end.
Figure 6-29 Force Conveyor Measurement Screen
"
NOTE
Forcing the conveyor will stop the oven, be careful if the oven is in production.
3. When the measurement is finished, check the real speed against the measured speed
(Figure 6-30). If the real speed is different from the measured speed, enter the
Real Speed
of
the conveyor. Next, click on the
Adjustment Real Speed/Measured Speed
button. The PLC
will automatically correct the calculation of the measured speed.
Figure 6-30 Force Conveyor Running Screen
Force Conveyor
Running Button
Speed
Setpoint
Adjust Real Speed /
Measured Speed
Summary of Contents for TC V3