Installation 19
Leveling the Cure Module
CAUTION!
This procedure should only be performed by a trained service technician.
"
NOTE
If your Cure Module is going to be used as an in-line system, it needs to be leveled and
aligned in relation to upstream and downstream systems. This manual does not include
alignment procedures for upstream/downstream systems. Alignment procedures should
be developed by your facility.
To level a stand-alone Cure Module:
1. Place the level in the center of the front conveyor rail, along the length of the rail.
2. Observe the position of the bubble within the level’s window. The bubble should be centered
indicating the Cure Module is level from side-to-side.
3. If necessary, adjust the Levelers (feet) as follows (Figure 4-1):
!
Loosen the locking nut.
!
Turn the Adjusting Nut in the desired direction until the level’s bubble is centered,
indicating that the system is level from side-to-side.
Figure 4-1 Leveler Height Adjustment
4. Check for all-around stability by putting your hands on top of the Cure Module in one corner
and pressing down. If one leveler is lower or higher than the others, the Cure Module will rock
back and forth. Adjust the levelers so that they are all bearing the weight equally.
5. Re-level the Cure Module from side-to-side and from front-to-back, if necessary.
6. Re-tighten the locking nuts on each foot after the machine has been completely leveled and
stabilized.
"
NOTE
Do not over-tighten the locking nuts. They only need to be snug.
Locking Nut
Pedestal
Adjusting
Nut
Leveler (foot)