Software
31
3. The Recipe Parameters screen appears (Figure 6-8). From this screen, you can:
•
Check the current recipe parameters
•
Select and download another recipe.
Figure 6-8 Recipe Parameters Screen
"
NOTE
If they are not correct, the values need to be changed. (Supervisor Mode – Access Level
2 required).
Table 6-1 Recipe Parameters Descriptions
Parameter
Description
Zx Setpoint (°C)
Temperature set point of the x zone, adjustable from 0 to
300°C.
AL2 Band Set Point (°C)
This value represents the tolerance between the actual
temperature and the requested temperature in °C. When
the Al2 is activated on one zone, the orange light is on.
When Al2 disappears on each zone, the green light and
the “oven ready signal” switch on.
Speed Set Point (cm/min)
This value is the requested conveyor speed in cm/min.
AL1 Speed Low Alarm
(cm/min)
This value is the lower limit of the conveyor speed, below
this alarm the red light turns on and the alarm sounds.
(see “
Alarms
” in the
Software
section of this manual for
further information)
AL2 Speed Band Setpoint
(cm/min)
This value represents the tolerance between the actual
value and the value requested in cm/min.
Length Hole in PCB
Setpoint (cm)
This parameter represents the number of holes seen by
the optical sensor on one board. Adjust this value to be
sure that the PLC counts the correct quantity of boards.
Humidifier (on/off)
The humidifier is activated according to the value of this
parameter.
Recipe Record
Name
Recipe
Parameters
Download
Recipe to PLC
Recipe Name
Drop Down List
Main Menu