12
Components
Type of Alarm
Cause
Oven Condition
Restart Condition
Loss Conveyor
Parameters Alarm
The conveyor parameters are
lost.
Oven ready signal off
Red tower light on
Alarm sounds
When conveyor is
recalibrated (refer to the
Maintenance Manual
)
PCB Spacing
Length Inferior
than PCB Hole
Max Length Alarm
PCB spacing length inferior
than PCB hole max length
Oven ready signal off
Red tower light on
Alarm sounds
When recipe parameters
are adjusted.
Reset alarm.
Dropped Board
Alarm (option)
The dropped board sensor is
activated
Heat and conveyor on
Oven ready signal off
Red tower light on
Alarm sounds
When the input exhaust
OK changes to 0.
Reset alarm.
Board Jam Alarm
(option)
The count sensor at the
conveyor output is sealed
longer than the maximum
delay defined in option
parameters menu.
Heat and conveyor on
Oven ready signal off
Red tower light on
Alarm sounds
When the sensor is not
activated.
Reset alarm.
Input Transfer
Alarm (option)
The delay between the “Send
PCB” signal from the
upstream machine and input
board sensor on the oven is
longer than the time defined in
the option parameters menu.
Oven ready signal off
Red tower light on
Alarm sounds
Reset alarm.
Output Transfer
Alarm (option)
During a delay, the
"downstream ready" signal is
down longer than the time
defined in the parameters
option menu.
Oven ready signal off
Red tower light on
Alarm sounds
Reset alarm.
Lubricator Alarm
(option)
The conveyor chain
lubrication oil level is below
the minimum level.
Alarm message received
Oven still in production
When oil level is raised.
Humidifier Alarm
(option)
There is a change in humidity
level.
Oven ready signal off
Red tower light on
Alarm sounds
When humidifier error
signal decreases to 0.
Reset alarm.