25
Hood Closing Procedure
•
Remove the safety pin to unlock and remove the bar.
•
Turn the two switches (Figure 5-3) at the same time until the alarm rings. This indicates that
the Hood is closed.
Setting Conveyor Clearance
To allow various board widths to be handled, the Cure Module is equipped with a conveyor system of
variable widths. The width adjustment Hand Crank of the conveyor is located on the front of the Cure
Module (Figure 5-5). Verify that the crank is placed in the opening labeled "CONVEYOR". Turn the crank
to move the adjustable rail to modify the rail width.
Figure 5-5 Hand Crank
WARNING!
Make sure that the oven is clear of all PCBs before adjusting conveyor width.
Failure to do so could cause damage to the equipment or workpieces.
"
NOTE
For nitrogen based systems the Cure Module is equipped with curtains to limit the
consumption of nitrogen. The clearance of the rail can vary depending on the
configuration.
CAUTION!
During production, the crank should be disengaged to prevent movement.
Hand Crank