background image

15

(617417440)

 FM226A 10/18

Access 800

™ 

TCAC2 Series

Locks

Keypad Programming Instructions

Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.  

All rights reserved. Reproduction in whole or in part without the express written 

permission of Corbin Russwin, Inc. is prohibited.

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

6

Chain Programming

When programming multiple Users and Codes into the M800, M801, M803, M804 and M806 Lock, it is 

not necessary to leave and re-enter the programming Mode (50) for each entry. Multiple entries may be 

chained together and the three different types of user codes (Standard, Passage and One Time) may be 

mixed.
The format to be used is as follows where:

“T” is the Type of user code with “1” = Standard, “0” = Passage and “5” = One Time. 

“UL_” is User Location (04-100 for M800 and 03-2000 for all others) 

“UC_” is User Code (2 to 6 digits) which correlates with the User Location

99# Master or Supervisor Code* 50# Type# User Location a# User Code a* User Code a*

Type# User Location b# User Code b* User Code b* T# ULc# UCc* UCc* T# ULd# 

UCd* UCd* ........ T# UL_# UC_* UC_** 

Example with four User Codes:

Using Master Code 4732 and above information, the lock would be programmed as follows:

99# 4732* 50# 1# 05# 875* 875* 3# 12# 2226* 2226* 2# 08# 5444* 5444* 1# 48# 3367* 3367*

If all user codes are the type 1, it is not necessary to enter the type number with each entry. 

The format now simplifies to:

99# Master or Supervisor Code* 50# User Location a# User Code a* User Code a* ULb# 

UCb* UCb* ULc# UCc* UCc* ........ UL_# UC_* UC_**

 

Example with three User Codes:

Using Master Code 45988 and above information, the lock would be programmed as follows:

99# 45988* 07# 77* 77* 15# 67832* 67832* 91# 7568* 7568**

To chain the User Location delete procedure:

99# Master Code* User Location a#** ULb#** ULc#**....... UL_#****

Using the information from the above example:

99# 45988* 07#** 15#** 91#****

Type

User Location

User Code

1

05

875

3

12

2226

2

08

5444

1

48

3367

Type

User Location

User Code

1

07

77

1

15

67832

1

91

7568

Summary of Contents for Corbin Russwin Access 800 TCAC2 Series

Page 1: ...MORTISE Important Access800 TCAC2 controllers have replaced Access800 controllers for the M801 M802 M803 M804 M805 and M806 Options first generation Access800 controllers for these options are no lon...

Page 2: ...tial by this user type will override any locked condition and will unlock the door including User Lockout and Panic Lockdown states Presentation of this user type also allows entry on a Access 800 mor...

Page 3: ...al times until the yellow LED goes out If no keystroke is made in a 30 second time frame the programming up to that point will default and you will have to start over Lock Model ______________________...

Page 4: ...ter the Emergency Code 99 Master Code Yellow LED blinks 50 02 Yellow LED blinks Emergency 1 6 digits Yellow LED blinks quickly Emergency 1 6 digits Yellow LED blinks slowly Yellow LED goes out Emergen...

Page 5: ...ode Yellow LED blinks slowly Yellow LED goes out Note The lock out user is location dependent and will lock out all users beyond this location To ensure that all users are locked out of the keypad pro...

Page 6: ...up to 5 digits Yellow LED blinks 0 Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Interrogate Transaction Log To output the last 1000 transactions 99 Supervisor or Master C...

Page 7: ...rogramming Transaction Descriptions Will vary Optional Equipment Printer Paper 6 Rolls 794F189 used for infrared printers Infrared Printer 793F109 used to download the user and transaction type To Res...

Page 8: ...rt corbinrusswin assaabloy com 4 M800 Programming Status Indicators No Green LED after code is entered once and 3 rapid beeps Invalid Code Three attempts will lock out for 10 seconds with Yellow LED 4...

Page 9: ...s also used for programming Users are deleted through the Master Programming Code only Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock TCAC2 locks allow...

Page 10: ...6 digits Yellow LED blinks quickly User Code 1 6 digits Yellow LED blinks slowly Yellow LED goes out Enter A Panic User Code 99 Master Code or Supervisor Code Yellow LED blinks 50 9 User Location 03...

Page 11: ...aster Code or Supervisor Code Yellow LED blinks 50 5 User Location 03 2000 Yellow LED blinks 1 6 Digits Yellow LED blinks quickly 1 6 Digits Yellow LED blinks slowly Yellow LED goes out Enter An Exten...

Page 12: ...Code Yellow LED blinks 50 See Table Below User Location 03 2000 Yellow LED blinks User Code 1 6 digits Yellow LED blinks quickly User Code 1 6 digits Yellow LED blinks slowly Present Card Tag FOB or R...

Page 13: ...wly Yellow LED goes out Turn ON Yellow LED verification on every Key Depression 99 Master Code Yellow LED blinks 30 1 1 On 0 Off Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Ye...

Page 14: ...Enable or 1 Disable User No 03 2000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Delete A User 99 Master Code or Supervisor Code Yellow LED blinks 50 0...

Page 15: ...User Code 2 to 6 digits which correlates with the User Location 99 Master or Supervisor Code 50 Type User Location a User Code a User Code a Type User Location b User Code b User Code b T ULc UCc UCc...

Page 16: ...eps are required 1 Use AccesswareTM software to set up your system and Hotsync door information to PDA 2 Remove Battery Cover from inside of lock 3 On PDA select Access HH then Imp Exp PDA Response Pl...

Reviews: