7

M802 and M805 Programming

In a Prox Only M802 or RF Technology & Prox M805 configuration, all programming must be completed 
using AccesswareTM Software. The Software includes a convenient Software User’s Manual in .pdf 
format to be used as a programming guide. After setting up your system using the software, Hotsync to 
the PDA. Be sure to program a “Communications Enable” credential for future programming.
To program the lock for the first time or after memory is reset, the following steps are required. 
1. Use AccesswareTM software to set up your system and Hotsync door information to PDA.
2. Remove Battery Cover from inside of lock.
3. On PDA - select “Access HH”, then “Imp/Exp”  

PDA Response: “Please enter your  

“Do 

NOT

 click OK at this point”  

communications code at the door”

4. “Wake up” the M802 or M805 lock by presenting 

any HID Prox Credential or by depressing an RF FOB   Lock Response: Audible beep

5. Within a couple seconds press and hold the controller CommEnable push button (white button 

located in the battery compartment) for 2 seconds, then release the button.

6. On the PDA, click “OK”  

The PDA will begin transferring (0-100%) of  

 

the door data to the lock.

If there was an error, check connections and repeat process starting at Step 3.

Note: The Credential will NOT actuate the lock for 45 seconds from the start of the downloading 
process. After this time expires, the Credential will function as defined by its User Type. 

Reprogramming
Note: Using the proximity card, FOB, tag or RF FOB programmed as a “CommEnable” User, 
present the “CommEnable” credential to the lock to initiate communications after performing 
Step 3 (above) without the need to press the CommEnable button.

Summary of Contents for Corbin Russwin Access 800 TCAC2 Series

Page 1: ...MORTISE Important Access800 TCAC2 controllers have replaced Access800 controllers for the M801 M802 M803 M804 M805 and M806 Options first generation Access800 controllers for these options are no lon...

Page 2: ...tial by this user type will override any locked condition and will unlock the door including User Lockout and Panic Lockdown states Presentation of this user type also allows entry on a Access 800 mor...

Page 3: ...al times until the yellow LED goes out If no keystroke is made in a 30 second time frame the programming up to that point will default and you will have to start over Lock Model ______________________...

Page 4: ...ter the Emergency Code 99 Master Code Yellow LED blinks 50 02 Yellow LED blinks Emergency 1 6 digits Yellow LED blinks quickly Emergency 1 6 digits Yellow LED blinks slowly Yellow LED goes out Emergen...

Page 5: ...ode Yellow LED blinks slowly Yellow LED goes out Note The lock out user is location dependent and will lock out all users beyond this location To ensure that all users are locked out of the keypad pro...

Page 6: ...up to 5 digits Yellow LED blinks 0 Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Interrogate Transaction Log To output the last 1000 transactions 99 Supervisor or Master C...

Page 7: ...rogramming Transaction Descriptions Will vary Optional Equipment Printer Paper 6 Rolls 794F189 used for infrared printers Infrared Printer 793F109 used to download the user and transaction type To Res...

Page 8: ...rt corbinrusswin assaabloy com 4 M800 Programming Status Indicators No Green LED after code is entered once and 3 rapid beeps Invalid Code Three attempts will lock out for 10 seconds with Yellow LED 4...

Page 9: ...s also used for programming Users are deleted through the Master Programming Code only Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock TCAC2 locks allow...

Page 10: ...6 digits Yellow LED blinks quickly User Code 1 6 digits Yellow LED blinks slowly Yellow LED goes out Enter A Panic User Code 99 Master Code or Supervisor Code Yellow LED blinks 50 9 User Location 03...

Page 11: ...aster Code or Supervisor Code Yellow LED blinks 50 5 User Location 03 2000 Yellow LED blinks 1 6 Digits Yellow LED blinks quickly 1 6 Digits Yellow LED blinks slowly Yellow LED goes out Enter An Exten...

Page 12: ...Code Yellow LED blinks 50 See Table Below User Location 03 2000 Yellow LED blinks User Code 1 6 digits Yellow LED blinks quickly User Code 1 6 digits Yellow LED blinks slowly Present Card Tag FOB or R...

Page 13: ...wly Yellow LED goes out Turn ON Yellow LED verification on every Key Depression 99 Master Code Yellow LED blinks 30 1 1 On 0 Off Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Ye...

Page 14: ...Enable or 1 Disable User No 03 2000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Delete A User 99 Master Code or Supervisor Code Yellow LED blinks 50 0...

Page 15: ...User Code 2 to 6 digits which correlates with the User Location 99 Master or Supervisor Code 50 Type User Location a User Code a User Code a Type User Location b User Code b User Code b T ULc UCc UCc...

Page 16: ...eps are required 1 Use AccesswareTM software to set up your system and Hotsync door information to PDA 2 Remove Battery Cover from inside of lock 3 On PDA select Access HH then Imp Exp PDA Response Pl...

Reviews: