14
(617417440)
FM226A 10/18
Access 800
™
TCAC2 Series
Keypad Programming Instructions
Locks
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
5
M801, M803, M804, M806 Programming
Set Unlock Time
99# Master Code* or Supervisor Code*
Yellow LED blinks
11# (1-255 sec.)# 0#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
The Unlock Time is adjustable for momentary operation. A 5 second unlock time is recommended to
extend battery life. Once unlock time is entered, it is the same for ALL users except Extended Users.
To Enable/Disable A User
99# Master Code* or Supervisor Code*
Yellow LED blinks
56# 0# (Enable) or 1# (Disable)
(User No. 03-2000)#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Delete A User
99# Master Code* or Supervisor Code*
Yellow LED blinks
50# 0# (User Number 03-2000)#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Clear the Entire Memory
99# Master Code*
Yellow LED blinks
46# 00000# 00000#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks rapidly, slowly when complete
*
Yellow LED goes out
Status Indicators
• No Green LED after code is entered once and 3 rapid beeps, but flashes after 3 consecutive entries
– Invalid Code
• 4 Long beeps after Standard code is entered - Low Battery
• 4 Long beeps after Standard code is entered, 4 more long beeps - Voltage (batteries) too low to
operate. Enter Master Code or Emergency Code to gain entry.
• 1 beep after User Code entered – Disabled User
• 4 beeps after User Code entered – Deadbolt Thrown (Mortise Lock Only)
• 3 beeps after User Code entered – User Lockout
• Alternating Red/Green LED – Awaiting second entry of Code and Card, Tag, or Fob User