M800 Programming
Sequence Number
Four digit – Rolling last 1000 transactions, 9999 is highest number
Latest transaction – Highest #, First to print
Oldest transaction – Lowest #, Last to print
User Location
Three digits - 001 through 100
(User numbers assigned at time of programming)
Transaction Descriptions
Will vary
Optional Equipment
Printer Paper (6 Rolls 794F189) used for infrared printers.
Infrared Printer 793F109 used to download the user and transaction type.
To Reset / Clear Transaction Log
99# Master Code*
Yellow LED blinks
76# 00000# 00000#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Clear the Entire Memory and restore Factory default settings
99# Master Code*
Yellow LED blinks
46# 00000# 00000#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks rapidly, slowly when complete
*
Yellow LED goes out
This deletes ALL Codes, including Master, Emergency and Supervisor. The Master Code is
set back to 1234*. Door Number to 0001 and Unlock Time to 5 seconds. If the Master Code
is not known, Factory Assistance will be required to clear the memory. Call 1-800-543-3658