Gate Controller ATC 100
18
10. Technical data
•
Supply voltage
U
E
3 x 400 V 50/60Hz main power supply for
three-phase drives
U
E
230 V 50/60Hz
main power supply for
one-phase drives
I
E
/ I
Emax
65 mA / 107 mA
current consumption
P / P
max
15 VA / 24,5 VA
power consumption
The maximum values are valid for the maximum
configuration of the controller and the maximum supply
of external 24V components.
•
External safeguarding
F
B
max. 10A
•
Internal safeguarding
F
i
T 2A / 250 V
glass tube fuse
5x20mm
•
Supply outputs 24 V DC
U
Out24V
24 V DC ± 15%
I
Outmax24V
250 mA
P
Outmax24V
6 W
To guarantee the correct function of the controller the
listed maximum values may not be exceeded in any case.
•
Motor reversing contactor
P
Smax230V
2,2 KW
max. contactor output
with 230 V one-phase
drives
P
Smax400V
4KW
with 400 V three-phase
drives
•
Relays
U
REL
250 V~
max. switching voltage
I
REL
2,5 A~
max. switching current
•
Switching times Safety device
T
A
≤
25 ms
STOP initiated
→
→
→
→
→
contactor open
T
A
≤
30 ms
ISK initiated
→
→
→
→
→
contactor open
•
Protection class
IP 54
Enclosure with cable glands/stagenipples
•
Weight
1,8 kg
•
Temperature range
-10° to +55° C
•
Store temperature
-20° to +70° C
•
Approvals
EN 12453
- "Safety in use of power operated doors/gates"
EN 12978
- "Safety devices for power operated gates"
Summary of Contents for 302030