4.4 Control switch inputs
Connect to the clamps 8 to 12 the control switches (normally
open contacts) for the Opening, Closing and Impuls. These
control switches can be implemented as switches, key-
operated push buttons, code lock or extern radio controller.
Depending of the settings for
"Impuls"
the impuls input
initializes the instruction sequence "open-stop close-stop
..."and/or "open, close, open ...". In the end positions of the
gate the impuls will initiate the corresponding moving of the
gate.
Open
Close
Impuls
8
9
10
11
Com
Com
12
8
9
10
11
12
4.5 Light-barrier inputs
Inputs for a light barrier, which is active in the closing
movement of the gate. Dependent on the settings an initiation
of the light barrier in the closing movement causes a STOP
with short or STOP with full reversion. Contrary to the full
reversion the automatic closing will be deleted with the short
reversion. If several light barriers are installed, the appropriate
light barrier contacts are to be switched in series.
If the input is not used the inputs 14, 15 are to be bridged
accordingly.
With activation of the "secondary-time" the function for quick
closing after crossing the light barrier can be realized in the
"automatic-mode". Instead of the adjusted open-time the
adjusted secondary-time is used as a new open-time after
crossing the light barrier..
4.3 STOP inputs
The STOP-inputs are inputs without a safety-related-function.
They are for the monitoring of STOP-signal generator (e.g.
STOP-button etc.).
The two inputs are internally switched in series. If a stop is
released, this causes an immediate stop in both directions
of travel and the message "STOP" appears in the display.
The STOP-chain is active in every program step, except the
gate end position. By the STOP-instructions all stored
instructions (e.g. automatic closing etc.) are deleted.
Therefore a new initial instruction must possibly be given
after clearance of the malfunction.
If an input and/or both inputs are not connected they are to
be bridged accordingly. If there are more than two STOP-
inputs needed the opener circles of the signal generators
have to be switched in series.
13
14
15
or bridge
Closing
LS
Direction
LS
OUT
+24V
GND
13
14
15
6
7
or bridge
STOP
STOP
5
6
7
5