17
9. Enclosure
ABS-Enclosure with cable glands and stage nipple cable
insertions.
9.1 Mounting of the enclosure
Before mounting the controller is to be examined for
possible transportation or other damages. If the electronic
or the enclosure is damaged the controller may not been
installed or taken in operation.
After removing the cover the enclosure can be fixed with
four screws.
Mounting on walls:
Wood screws 4x40mm with 6mm dowel
Mounting on the gate:
Tapping screw 4x20mm or machine screw M4x20mm
The ATC 100 is to be fastened professionally with all
four screws to a suitable mounting place with even
underground.
The ATC100 is designed for a vertical mounting.
In order to prevent infiltrating humidity through the cable
glands, the enclosure should be installed in such a way
that the cable glands point downwards.
The weight of the controller of approx. 1,8kg should be
absolutely considered with the choice of the mounting.
9.2 Enclosure dimensions
22
8
24
0
Mo
un
tin
g
hol
es
4x
4
,2
m
m
27
5
130
160
75
90
15
7. Jumper settings:
With the 2 jumpers on the board general functions can
be adjusted.
•
Jumper J1:
automatic closing
J1 open:
automatic closing deactivated
J1 bridged:
automatic closing activated
•
Jumper J2:
ISK-Safety system
J2 open:
ISK-Safety system activated
J2 bridged:
ISK-Safety system deactivated
8. Article numbers
ATC100
compl. with enclosure, control module
302030
ATC100
only electronic without controle module
302031
Control modul for
ATC100
302033
Enclosure
for ATC100
302034
Plug-on module ISK 70-75
204160
Plug-on module ISK 70-75
204162
in the set with SPK9 and SPK 12
Time switch ZU 3
550103
Radio receiver HE single channel
515110
with antenna
Hand transmitter HE single-channel
514001
Hand transmitter HE dual-channel
514002
Hand transmitter HE quad-channel
514004