Gate Controller ATC 100
12
16
17
18
19
20
ISK
Coil Core
Safety Edge
Opening
Safety Edge
Closing
SKL
SKL
16
17
18
19
20
8,
2
k
Ω
8,
2k
Ω
The installation without safety contact edges and/or without ISK-system may only be used on gate-systems
which have their own and to the latest standards confirming safety devices. Gate systems without safety
devices may only operated in manual mode to prevent severe injuries.
The liability of the manufacturer is terminated with neglect or deliberate abuse.
4.7 Limit switch inputs
The limit switches OPEN
(Limit Switch OP) and the limit
switch CLOSE
(Limit Switch CL) are monitored permanently
and are stringently necessary for the allocation of the actual
end position. The limit switches can be implemented e.g. as
rolling- or inductive limit switch (normally close contact).
If end position OPEN and end position CLOSE is detected
at the same time the program stops. The signal "ERROR
end positions" is indicated in the display.
21
22
23
+24V
0V
Limit Switch
24
OP
CL
4.6 Safety contact edges connection
Stationary safety contact edges
The direction depending monitoring of the stationary safety
contact edges takes place directly on the ATC 100. The
contact edges working against the driving direction have no
influence to the program sequence. If the automatic closing
is activated an actuating of the contact edges will reset the
automatic closing till the next start-up signal.
Not used inputs must be terminated with a 8,2 k
Ω
resistor.
Travelling safety contact edges
The direction depending monitoring of the safety contact edges
travelling with the gate (
sliding gates applications) takes
place via the optionally plug-on inductive safety system ISK
70-75 electronic. The contact edges working against the
driving direction have no influence to the program sequence.
If the automatic closing is activated an actuating of the
contact edges will reset the automatic closing up to the next
start-up signal. Please take the detailed description and the
assembly instruction for the ISK-system from the current
ISK documentation.
4.8 Power supply output 24 V
For the supply of external consumers the ATC 100 provides
a power supply output with 24V DC
±
15%.
For gates where no ISK modules is needed (roller-, revolving-, sectional-doors etc.) the function of the ISK-system
can be deactivated. For this the jumper J2 is to be bridged.
This 24 V power supply output may be loaded with
max. 250 mA..
21
22
+24V
GND
24V DC for ext. consumer
(max. 250 mA)