Remove four T-15 Torx screws securing the lower rear panel.
Carefully pull top of panel out first, then release the tab from the slot in the base of the unit.
The circulation pump & capacitor are accessed from the rear by removing the rear lower panel.
Before beginning always drain all water from the sump and disconnect power to the unit
Circulation Motor / Pump (3,000 series)
Screws
Screws
The circulation Motor has a resistance of
22 ohms and an attached 16 micro farad capacitor.
The motor uses 95 watts of power when operating
.
22