Water Fill Valve with flow meter (3,000 series)
(front access)
Remove connector from flow meter
Connector
Fill valve is connected to flow meter
with a push/turn bayonet type fitting
The flow meter is
connected to the rear
of the fill valve. The
whole assembly can
be replaced by
removing the hose
which goes up to the
air break. A new hose
clamp will then be
needed to reconnect
the new assembly. Or
the flow meter can be
disconnected from
the fill valve via the
retaining clip or with
the bayonet fitting
Clip
Bayonet
fitting
Flow
Meter