Water Valve (5,000 series) removal
(rear access)
Disconnect pex hose and Molex
connector from valve
Cut through retaining clamp with cutters
Retaining clamp
Bend tab at rear of air break
Pull valve from air break
The fill valve on the 5,000
series is attached to the air
break and is accessed from the
rear of the unit. The only way to
remove the valve from the air
break is to cut through the
retaining clamp (the new valve
is a kit and will come with a
new clamp). Bend the tab at
the rear of the air break away
from the valve, then pull on the
valve to release from the
housing
1
2
3
4