Heating Element
Access to the heating element is achieved from the rear of the unit in the same manor as the circulation
motor/pump. The heating element is suspended between the circulation pump housing and the sump
housing and is secured with rubber seal inserts. It is a push fit and there are no clamps. The circulation
motor will have to be removed first in order to pull the heating element off of the sump.
Before removing the heating element disconnect the ground wire and the Molex connector.
Caution
Connection rods run from the heater to the Molex on the outside of the casing and are hot all the time so
make sure the power is off before removal. Heating Element is
1200 Watts Resistance 12 Ohms