Serial Port Output
87
Serial Port Output
Note: In the MBEN message, goodbad = 25 and warning = 35 implies Z-tracking
(non-keyed operation). If it is in Y-mode (keyed operation), gotmeas flag will be
24.
PBEN Message
PBEN messages contain position data, including velocity data, DOP values, and
time. PBEN can be output in ASCII or binary format. Table 4.7 and Table 4.8
below outline the contents of the PBEN message in binary and ASCII format.
The structure of the PBEN message in binary format is shown below:
Table 4.5.
Warning Flag Settings
Bits Index
Description of parameter d
7
1
2
Combination of bit 1 and bit 2
0
0
1
0
1
0
same as 22 in good/bad flag
same as 24 in good/bad flag
same as 23 in good/bad flag
3
carrier phase questionable
4
code phase (range) questionable
5
range not precise (code phase
loop not settled)
6
Z tracking mode
7
possible cycle slip
8
loss of lock since last epoch
Table 4.6.
Measurement Quality [Good/Bad Flag]
Value of d
8
Description
0
Measurement not available and no additional data is sent
22
Code and/or carrier phase measured
23
Code and/or carrier phase measure, and navigation mes-
sage was obtained but measurement was not used to com-
pute position
24
Code and/or carrier phase measured, navigation message
was obtained, and measurement was used to compute
position