Getting Started
13
Getting S
tarted
S/N
is the serial number of the receiver.
OPT
is a list of option codes, as listed in Table 2.1. The order is important. A
dash (-) means your receiver does not have the corresponding option.
OPT SLOT NO
indicates how many times options have been reloaded into the
receiver
SLP
indicates the version of the sleep mode firmware, and its release date
NAV
indicates the version of navigation firmware and its compilation date.
CHAN
indicates the version of channel firmware and its compilation date.
Saving and Resetting User Parameters
When the values of most parameters are modified, they are not saved
automatically in the internal memory overriding the defaults, and resets after a
power cycle of the receiver.
Modified parameters can be saved by using the command 555. To use this
command, from Screen 8, press the
[e]
key, enter 555 and press
[e]
again. The
message "
user parameters saved
" displays.
To set parameters back to their original default values, use command 550. To use
this command, in Screen 8, press the
[e]
key, enter 550, and press
[e]
again. The
message "
default parameters being restored
" displays.
Table 2.1.
Option Codes
Code
Installed Option
D or U
D = differential
U = remote only
P
Photogrammetry
1
P1
2
P2
M
Remote monitoring
X
External frequency
-
Reserved
-
Reserved
L
Sleep mode
-
Reserved