8) Removing the Workpiece
(1) Turn the Rack Handle counterclockwise and return the Carriage.
(2) Loosen the Hammer Chuck.
(3) Loosen the Scroll and pull out the workpiece.
9) Cleaning after Use
* Remove chips scattered on the machine or in the area.
* Use a wire brush and clean and remove chips from the Chuck, Dies of Die-Head and Reamer.
* Use waste cloth and wipe off the threading oil splashed over the machine and the area.
25
• The workpiece is wet and slippery with threading oil. Use utmost care not
to drop on your feet.
• Do not blow off chips using air. They may get into eyes and loss of
eyesight may result.
• Chips are sharp. Do not touch them with bare hand. Always wear gloves.