FAB2 Intelligent Controller
Digital Output
Output type Output voltage Output Current
Transistor output( equivalent NPN)
Short Circuit and Overload Protection
≤DC80V
Current limit of short circuit
Max. 2A
Reduction of the rated value
No
Output type Output voltage Output Current
about 2A
Short Circuit and Overload Protection
No( even in the whole temperature range)
2.6 AF-10MR-E2/AF-20MR-E2
Power supply
The rated Voltage of power supply
AC/DC12V-AC/DC24V
Allowable range of the rated input voltage
AC/DC10V-28V
Power Consumption (AC/DC24V)
(Output full load)
AF-10MR-E2(3W)
AF-20MR-E2(5W)
Digital Input
Signal 0
Signal 1
<AC/DC4.5V
AC/DC10-24V
Input current of Signal 1
Typical 2mA
Input section (analog input)
Typical 50ms
Typical 50ms
The length of power line(without shield)
100m
Digital output
Output Type
Relay output
Electrical Isolation
Yes
Group
1
Continuous current Ith
Max.10A
Incandescent Lamp Load
(25,000 switch cycles)
1000W
Fluorescent Light Tube With Electrical
Controller (25,000 Switch cycles)
10×58W
Fluorescent Light Tube With Regular
Compensation (25,000Switch cycles)
1×58W
Fluorescent Light Tube without
Compensation (25,000 Switch Cycles)
10×58W
Short Circuit Protection cos1
Power supply protection B16 600A
121
Summary of Contents for AF-10MR-A2
Page 1: ......
Page 11: ...FAB2 Intelligent Controller MEMO 10...
Page 43: ...FAB2 Intelligent Controller MEMO 42...
Page 57: ...FAB2 Intelligent Controller 56 MEMO...
Page 74: ...FAB2 Intelligent Controller MEMO 73 Fig 1 11 The semoval screen of Quick II...
Page 78: ...FAB2 Intelligent Controller 77 MEMO...
Page 116: ...FAB2 Intelligent Controller MEMO 115...
Page 124: ...FAB2 Intelligent Controller MEMO 123...
Page 126: ...FAB2 Intelligent Controller MEMO 125...
Page 128: ...FAB2 Intelligent Controller 127...
Page 129: ......