Lightning LS-1
Section 3
Pilot's Operating Handbook
Emergency Procedures
Issue B
3-11
"HIGH VOLTAGE" WARNING
1.
Throttle..............................REDUCE as necessary to
reduce alternator output, but NOT enough to cause
an unsafe flight condition
2.
Master Switch.................................................CYCLE
If high voltage warning continues:
3.
Master Switch.....................................................OFF
unless electricity is essential to safety of flight
4.
Aircraft...............................LAND as soon as practical
CIRCUIT BREAKER TRIP
1.
Circuit Breaker................NOTE tripped circuit breaker
2.
Equipment on tripped circuit breaker................... OFF
3.
Circuit Breaker................................................RESET
If circuit breaker trips again, DO NOT RESET:
4.
Aircraft...............................LAND as soon as practical
MASTER SWITCH CIRCUIT BREAKER TRIP
1.
Aircraft...............................LAND as soon as practical
2.
Master Switch Circuit Breaker.........................RESET
by flipping switch to ON position
3.
Engine..............................................................RUN
If main circuit breaker trips again:
4.
RECTIFY before continuing flight.