Section 3
Lightning LS-1
Emergency Procedures
Pilot’s Operating Handbook
Page 3-8
Issue B
3.5 Fire Procedures
FIRE DURING START ON GROUND
1.
Cranking.................................................CONTINUE
to get a start, which would suck the flames and
accumulated fuel through the carburetor and into the
engine.
If engine starts:
2.
Power......................................................1500 RPM
3.
Fuel Boost Pump...............................................OFF
4.
Fuel Selector Valve............................................OFF
and allow engine to empty carburetor
5.
Engine..................................INSPECT for damage
If engine fails to start:
6.
Ignition..............................................................OFF
7.
Fuel Selector Valve..............................CONFIRM OFF
8.
Electrical Switches..............................................OFF
9.
Aircraft.............................................................EXIT
10.
Fire................................................EXTINGUISH
using fire extinguisher, wool blanket, or dirt.
11.
Fire Damage....................INSPECT AND REPAIR