Lightning LS-1
Section 7
Pilot's Operating Handbook
Description of Airplane & Systems
Issue B
7-9
settings: LEFT, RIGHT, and OFF. LEFT draws fuel
from the left wing tank, RIGHT draws fuel from the
right wing tank, and OFF shuts off the fuel supply to
the engine at the location of the selector valve.
FUEL SUMPS
The aircraft has two fuel sumps with quick-drain
valves that must be checked during preflight
operations. The wing sump quick-drain valves are
located just outboard of the fuselage on the
underside of each wing.
CARBURETOR
Manufacturer.........................................Bing Agency
Model..................Type 94/40 pressure-compensating
Each LS-1 carburetor is set up for proper jetting in an
average climate before leaving the factory. Operation
in extreme climates or out of high mountain airports
may require an adjustment to carburetor jetting for
optimum engine performance. Consult the LS-1
Maintenance Manual for more information on
adjusting the jetting.