Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 17
www.argo-hytos.com
9.3
Data collection
The filter unit FAPC 016 is equipped with a data memory that can store up to 3,000 results.
Once the storage capacity is reached, the last measured value is saved, while the oldest measured value is simultaneously overwritten.
The stored results are transferred to the hard disk of the connected PC or laptop and can be stored there.
Fig. 5: Three-way stopcock
NOTE
A description for installation and data transmission is available in the OPCom user manual.
1. Connect a data cable to the RSR232 socket (Fig. 1 Pos. 13).
2. Connect the plug to a PC or laptop on which the corresponding software is installed.
Switch position upstream of filter
›
horizontal level position
›
the oil cleanliness is monitored during the cleaning process
Switch position downstream of filter
›
vertical lever position
›
the oil cleanliness is monitored during the filling process
NOTE
The corresponding software can be downloaded from www.argo-hytos.com.
9.4
Switching of the measuring type while filling or cleaning
When monitoring the cleanliness class, a ball valve can be used to switch between "downstream of filter" (e.g. when filling the
equipment) and "upstream of filter" (e.g. when cleaning out oil fillings).
Switch positions are changed using the attached three-way stopcock (Fig. 1 Pos. 6).
downstr
eam of filter
upstream of filter