Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 20
www.argo-hytos.com
10.3.1 Removing the filter element
Fig. 7: Removing the filter element
1. Turn the housing cover (1) counterclockwise.
2. Carefully remove the cover (1) with the filter element (2)
from the filter tube.
(The filter element is attached to the cover.
Let the draining oil drip off into the housing.)
Fig. 8: Removing the filter element from the cover
1. Push the filter element at the cover in arrow direction 1 and
remove it in arrow direction 2.
2. Dispose of the filter element according to the national
environmental legislation (Waste code: Oil filter 16 01 07).
10.3.2 Removing the filter element from the cover
10.3.3 Attaching the filter element
Fig. 9: Attaching the filter element
1. Check the filter element type number.
Does the laser inscription on the filter element match with
the indications on the type plate or in the operating manual?
2. Attach the filter element in arrow direction 2 and lock it in
arrow direction 1.
1
2