Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 21
www.argo-hytos.com
10.3.4 Installing the filter element
1. Always replace the O-ring in the cover, when changing the
filter element (part of the scope of delivery of the filter
element) (O-ring Order No. N007.1175, included in spare
filter elements).
2. Carefully insert the cover (1) with the filter element (2) into
the filter tube.
3. Screw in the cover manually until it stops.
A gap between cover and filter pipe may remain visible
(see Chapter 8.1 "Before commissioning" / Fig. 3)
1
2
10.3.5 Bleeding the filter element
1. Open the bleed screw (1).
2. Plug in the mains plug and put the filter unit back into
operation. When oil begins to run out from the vent
opening, reseal the vent opening by tightening the bleed
screw (1).
3. Check whether the ventilation slots of the electric motor are
contaminated and remove any deposits that may be
present.
4. Restart the unit.
5. Check the filter housing for leaks after commissioning.
Fig. 10: Installing the filter element
Abb. 11: Bleeding the filter element
1
1